Analysis
Please Note
-
Specific Gravity
- Densitometry
- |
- 24 hours
- |
- 50 mL
$32.00
Visit product page →Specific gravity is the measurement of the density of a substance relative to the density of water.
Minimum Volume Required: 50mL
IncludesSpecific Gravity
(Units: Numerical, Technique: Densitometry) -
Standard Panel
- Various
- |
- 24 hours
- |
- 120 mL
$120.00
Visit product page →A comprehensive set of analyses for monitoring wine post-fermentation to the bottling line. Our standard panel includes all the analyses that are critical for decision making throughout the winemaking process.
Minimum Volume Required: 120mL
Includes
Alcohol by Volume
(Units: % vol, Technique: NIR)pH
(Units: pH, Technique: Manual)Titratable Acidity (TA)
(Units: g/L, Technique: Auto-Titration)Volatile Acidity (as Acetic Acid)
(Units: g/L, Technique: Sequential Analyzer)L-Malic Acid
(Units: g/L, Technique: Sequential Analyzer)Glucose + Fructose
(Units: g/L, Technique: Sequential Analyzer)Free & Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer) -
Standard Panel Non-Wine
- Various
- |
- 24 hours
- |
- 120 mL
$120.00
Visit product page →A comprehensive set of analyses for monitoring wine post-fermentation to the bottling line. Our standard panel includes all the analyses that are critical for decision making throughout the winemaking process.
Minimum Volume Required: 120mL
Includes
Alcohol by Volume
(Units: % vol, Technique: NIR)pH
(Units: pH, Technique: Manual)Titratable Acidity (TA)
(Units: g/L, Technique: Auto-Titration)Volatile Acidity (as Acetic Acid)
(Units: g/L, Technique: Sequential Analyzer)L-Malic Acid
(Units: g/L, Technique: Sequential Analyzer)Glucose + Fructose
(Units: g/L, Technique: Sequential Analyzer)Free & Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer) -
Tartaric Acid
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$30.00
Visit product page →The measurement of tartaric acid in wine and juice. Acid adjustments are typically made in wine and juice using tartaric acid.
Minimum Volume Required: 50mL
Includes
Tartaric Acid
(Units: g/L, Technique: Sequential Analyzer) -
Tartaric Acid Trial
- Incubation + Turbidimeter
- |
- 2 business days
- |
- 375 mL
$85.00
-
Titratable Acidity (TA)
- Auto-Titration
- |
- 24 hours
- |
- 50 mL
$20.00
Visit product page →The measurement of titratable acidity reflects the total available hydrogen ions in a wine or juice sample. As tartaric acid is the most prevalent acid found in grapes, TA results are reported as such.
Minimum Volume Required: 50mL
Includes
Titratable Acidity
(Units: g/L, Technique: Auto-Titration) -
Titratable Acidity + pH
- Various
- |
- 24 hours
- |
- 50 mL
$35.00
Visit product page →The measurement of titratable acidity reflects the total available hydrogen ions in a wine or juice sample. As tartaric acid is the most prevalent acid found in grapes, TA results are reported as such.
pH is the measurement of the concentration of hydrogen ions in a solution. The pH of wines are generally between pH 3.00 and pH 4.00. pH is a factor in many aspects of wine and winemaking, affects microbial stability and is used to determine molecular SO2.
Minimum Volume Required: 50mL
Includes
Titratable Acidity
(Units: g/L, Technique: Auto-Titration)pH Analysis
(Units: pH, Technique: Manual) -
Total Dry Extract
- Densitometry
- |
- 24 hours
- |
- 50 mL
$28.00
Visit product page →The measurement of non-volatile matter in wine, calculated using the alcohol and specific gravity of the sample. Total dry extract may be required for export purposes.
Minimum Volume Required: 50mL
IncludesTotal Dry Extract
(Units: g/L, Technique: Densitometry) -
Total Sugar (Glucose + Fructose, Inverted)
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$40.00
Visit product page →Total Sugar measures glucose + fructose (reducing sugars) along with sucrose (non reducing sugar).
Minimum Volume Required: 50mL
Includes
Glucose + Fructose + Sucrose
(Units: g/L, Technique: Sequential Analyzer) -
Total Sulfur Dioxide (SO2) - Aeration/Oxidation
- Aeration Oxidation
- |
- 24 hours
- |
- 50 mL
$35.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Aeration/Oxidation) -
Total Sulfur Dioxide (SO2) - Ripper
- Ripper
- |
- 2 days
- |
- 50 mL
$40.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Ripper) -
Total Sulfur Dioxide (SO2) - Sequential Analyzer
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$19.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer) -
Turbidity
- Turbidimetry
- |
- 24 hours
- |
- 50 mL
$20.00
Visit product page →The measurement of the clarity of a wine or juice. Turbidity measurements can be used to determine the need for fining or filtration.
Minimum Volume Required: 50mL
IncludesTurbidity
(Units: NTU, Technique: Turbidimetry) -
VI1 Export Panel
- Various
- |
- 5-7 days
- |
- Ready for Market Package
$250.00
Visit product page →This comprehensive panel is made up of analyses that are requested by certain EU countries for the Standard VI1 Form. Always check with your exporter as their requirements may differ.
Note: Lodi Wine Labs export analysis requires a ready for market package. Full labeling and complete packaging on the bottle is required.
Alcohol
(Units: % vol, Technique: NIR)Volatile Acidity
(Units: g/L, Technique: Sequential Analyzer)Titratable Acidity
(Units: g/L, Technique: Auto-Titration)Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer)Total Sugar
(Units: g/L, Technique: Sequential Analyzer)Total Dry Extract
(Units: g/L, Technique: Densitometry)Citric Acid
(Units: g/L, Technique: Sequential Analyzer) -
Vietnam Export Panel
- Various
- |
- 5-7 days
- |
- Ready for Market Package
$475.00
Visit product page →This comprehensive panel is made up of analyses that are most often requested by the Philippines. Always check with your exported as their requirements may differ.
Note: Lodi Wine Labs export analysis requires a ready for market package. Full labeling and complete packaging on the bottle is required.
Includes
Free and Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer)Molecular Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Calculation)Total Dry Extract
(Units: g/L, Technique: Densitometry)Volatile Acidity VA (as Acetic Acid)
(Units: g/L, Technique: Sequential Analyzer)Methanol
(Units: mg/L, Technique: Gas Chromatography)Sorbic Acid
(Units: mg/L, Technique: Distillation/Spectroscopy)Titratable Acidity
(Units: g/L, Technique: Auto-Titration)pH
(Units: pH, Technique: Manual)Total Sugar
(Units: g/L, Technique: Sequential Analyzer)Alcohol
(Units: % vol, Technique: NIR)Lead
(Units: ug/L, Technique: ICP-MS)Volume per Bottle
(Units: mL, Technique: Manual) -
Volatile Acidity VA (as Acetic Acid)
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$31.00
Visit product page →The measurement of acetic acid in a wine or juice, commonly referred to as volatile acidity. It is typically associated with a vinegar aroma and is considered undesirable at elevated levels.
Minimum Volume Required: 50mL
Includes
Volatile Acidity
(Units: g/L, Technique: Sequential Analyzer) -
Volume per Bottle - Fill Height
- Manual
- |
- 24 hours
- |
- Ready for Market Package (750mL)
$49.00
Visit product page →Fill height or volume per bottle is the measure of the exact volume of sample in a bottle. This measurement may be required for export requirements.
Minimum Volume Required: Ready for market package
Includes
Volume per Bottle
(Units: mL, Technique: Manual) -
WineScan Harvest Panel
- Various
- |
- 24 hours
- |
- 50 mL
$50.00
Visit product page →For Grape Juice Only
Description
Affordable rapid wine test using FTIR technology. The results are approximations based on absorbance.Includes
°Brix
(Units: % w/w, Technique: FTIR)pH
(Units: g/L, Technique: FTIR)Titratable Acidity (TA)
(Units: g/L, Technique: FTIR)Malic Acid (ML)
(Units: g/L, Technique: FTIR)Alpha Amino Nitrogen (N-OPA)
(Units: mg/L, Technique: FTIR)Ammonia (NH3)
(Units: mg/L, Technique: FTIR)Glucose
(Units: g/L, Technique: FTIR)Fructose
(Units: g/L, Technique: FTIR)Potassium
(Units: mg/L, Technique: FTIR) -
Winescan Juice Panel
- Various
- |
- 24 hours; Juice (Same Day)
- |
- 120 mL
$25.00
Visit product page →A routine set of analysis for juice and berry composition.
Note: Sample submissions of grape clusters will be charged a processing fee per sample for cluster preparation.
Minimum Volume Required: 120mL
Includes
°Brix
(Units: % w/w, Technique: FTIR
pH
(Units: pH, Technique: FTIR)
Titratable Acidity (TA)
(Units: g/L, Technique: FTIR) -
Winescan Monthly Monitoring Panel
- Various
- |
- 24 hours; Juice (Same Day)
- |
- 120 mL
$25.00
Visit product page →A routine set of analysis for wine.
Minimum Volume Required: 120mL
Includes
Free and Total SO2
(Units: mg/L, Technique: FTIR
Volatile Acidity
(Units: g/L, Technique: FTIR) -
WineScan Wine Panel
- Various
- |
- 24 hours
- |
- 50 mL
$50.00
Visit product page →For Grape Wine Only
Description
Affordable rapid wine test using FTIR technology. The results are approximations based on absorbance.Includes
Alcohol by Volume
(Units: % vol, Technique: FTIR)pH Analysis
(Units: g/L, Technique: FTIR)Titratable Acidity (TA)
(Units: g/L, Technique: FTIR)Volatile Acidity
(Units: g/L, Technique: FTIR)Malic Acid (ML)
(Units: g/L, Technique: FTIR)Glucose + Fructose
(Units: g/L, Technique: FTIR)Free & Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: FTIR) -
Yeast Assimilable Nitrogen (YAN)
- Sequential Analyzer
- |
- Same Day
- |
- 50 mL
$58.00
Visit product page →The measurement of yeast assimilable nitrogen is used to calculate the concentration of the total nitrogen in a wine or juice. These components are alpha amino nitrogen (N-OPA) and Ammonia (NH3). This measurement informs nutrient requirement decisions before and during fermentation.
Minimum Volume Required: 50mL
Includes
Yeast Assimilable Nitrogen (YAN)
(Units: mg/L, Technique: Sequential Analyzer) -
Zinc
- MP-AES
- |
- 24 hours
- |
- 50 mL
$32.00
Visit product page →The measurement of zinc present in wine and juice. Zinc can be found in a sample due to uptake from the soil.
Minimum Volume Required: 50mL
IncludesZinc
(Units: mg/L, Technique: MP-AES)
- Previous
- Page 3 of 3
- Next