Analysis
Please Note
-
Alpha Amino Nitrogen (N-OPA)
- Sequential Analyzer
- |
- Same Day
- |
- 50 mL
$26.00
Visit product page →N-OPA refers to one of the two prominent forms (along with NH3) of nitrogen that serve as yeast nutrients. The determination of the enzyme of the reaction or N-OPA is commonly measured along with NH3 to determine YAN (Yeast Assimilable Nitrogen).
Minimum Volume Required: 50mL
Includes
Alpha Amino Nitrogen (N-OPA)
(Units: g/L, Technique: Sequential Analyzer) -
Aluminum
- MP-AES
- |
- 24 hours
- |
- 50 mL
$32.00
Visit product page →The measurement of aluminum present in wine or juice.
Minimum Volume Required: 50mL
Includes
Aluminum
(Units: mg/L, Technique: MP-AES) -
Aluminum Packaging Panel
- Various
- |
- 1-2 days
- |
- 250mL
$275.00
Visit product page →This panel is designed to evaluate suitability of wines for aluminum packaging, and is based on recommendations from major industry suppliers, please consult with your provider to confirm what specifications they require.
Minimum Volume Requirements: 375mL
Includes
chloride (as sodium chloride)Free Sulfur Dioxide (SO2)Molecular Sulfur Dioxide (SO2)Oxygen - Dissolved O2pHTotal Sulfur Dioxide (SO2)Ethanol -
Ammonia
- Sequential Analyzer
- |
- Same Day
- |
- 50 mL
$26.00
Visit product page →Ammonia refers to one of the two prominent forms (along with N-OPA) of nitrogen that serve as yeast nutrients. The determination of ammonia is commonly measured along with N-OPA to determine YAN (Yeast Assimilable Nitrogen).
Minimum Volume Required: 50mL
Includes
Ammonia
(Units: mg/L, Technique: Sequential Analyzer) -
Brix by Densitometry
- Densitometry
- |
- 24 hours; Juice (Same Day)
- |
- 50 mL
$29.00
Visit product page →Measurement of the approximate sugar concentration in juice and must reported as percentage by weight. One gram of sucrose in 100mL of solution is considered a degree Brix. (°Brix)
Minimum Volume Required: 50mL
Includes
°Brix
(Units: Degrees, Technique: Densitometry) -
Brix by Digital Refractometer
- Digital Refractometer
- |
- 24 hours; Juice (Same Day)
- |
- 50 mL
$15.00
Visit product page →Measurement of the approximate sugar concentration in juice and must reported as percentage by weight. One gram of sucrose in 100mL of solution is considered a degree Brix. (°Brix)
Minimum Volume Required: 50mL
Includes
°Brix
(Units: Degrees, Technique: Digital Refractometer) -
Density
- Densitometry
- |
- 24 hours
- |
- 50 mL
$30.00
Visit product page →Measurement of the mass per volume of wine or juice.
Minimum Volume Required: 50mL
Includes
Density
(Units: mg/L, Technique: Densitometry) -
Filterability Index
- Manual
- |
- 24 hours
- |
- 750 mL
$55.00
Visit product page →The Filterability Index is the measurement of the difference in time from the filtration of 200mL of the wine (multiplied by a factor of two) and the filtration of 400mL of the wine.
Minimum Volume Required: 750mL
Includes
Filterability Index
(Units: FI, Technique: Manual) -
Free & Total Sulfur Dioxide (SO2) - Sequential Analyzer
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$38.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Free and Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer) -
Free Sulfur Dioxide (SO2) - Aeration/Oxidation
- Aeration Oxidation
- |
- 24 hours
- |
- 50 mL
$35.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine.
Minimum Volume Required: 50mL
Includes
Free Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Aeration/Oxidation) -
Free Sulfur Dioxide (SO2) - Ripper
- Ripper
- |
- 24 -48 hours
- |
- 50 mL
$50.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine.
Minimum Volume Required: 50mL
Includes
Free Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Ripper) -
Free Sulfur Dioxide (SO2) - Sequential Analyzer
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$19.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine.
Minimum Volume Required: 50mL
Includes
Free Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer) -
Glucose + Fructose
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$27.00
Visit product page →The measurement of glucose and fructose is used to determine the amount of sugar present in juice and wine. This measurement is also referred to as residual sugar.
Minimum Volume Required: 50mL
Includes
Glucose + Fructose
(Units: g/L, Technique: Sequential Analyzer) -
Glucose + Fructose Panel
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$58.00
Visit product page →The measurement of glucose and fructose is used to determine the amount of sugar in juice and wine. This panel gives the individual measurements of both glucose and fructose.
Minimum Volume Required: 50mL
Includes
Glucose + Fructose
(Units: g/L, Technique: Sequential Analyzer)Fructose
(Units: g/L, Technique: Sequential Analyzer)Glucose
(Units: g/L, Technique: Sequential Analyzer) -
Harvest Panel
- Various
- |
- 24 hours; Juice (Same Day)
- |
- 120 mL
$120.00
Visit product page →A routine set of analysis for juice composition prior to fermentation.
Minimum Volume Required: 120mL
Includes
°Brix
(Units: % w/w, Technique: Densitometry)pH
(Units: pH, Technique: Manual)Titratable Acidity (TA)
(Units: pH, Technique: Auto-Titration)L-Malic Acid
(Units: g/L, Technique: Sequential Analyzer)Glucose + Fructose
(Units: g/L, Technique: Sequential Analyzer)Alpha Amino Nitrogen (N-OPA)
(Units: g/L, Technique: Sequential Analyzer)Ammonia
Yeast Assimilable Nitrogen (YAN)
(Units: g/L, Technique: Sequential Analyzer)
(Units: g/L, Technique: Sequential Analyzer) -
Juice Panel
- Various
- |
- 24 hours; Juice (Same Day)
- |
- 120 mL
$45.00
Visit product page →A routine set of analysis for juice and berry composition.
Note: Sample submissions of grape clusters will be charged a processing fee of $7 per sample for cluster preparation.
Minimum Volume Required: 120mL
Includes
°Brix
(Units: % w/w, Technique: Densitometry)
pH
(Units: pH, Technique: Manual)
Titratable Acidity (TA)
(Units: g/L, Technique: Auto-Titration) -
L-Malic Acid
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$29.00
Visit product page →L-Malic acid is an organic acid found in grapes that is converted to lactic acid during secondary fermentation. The measurement of malic acid is useful for monitoring the progress of malolactic fermentation.
Minimum Volume Required: 50mL
Includes
L-Malic Acid
(Units: g/L, Technique: Sequential Analyzer) -
Magnesium
- MP-AES
- |
- 24 hours
- |
- 50 mL
$40.00
Visit product page →The measurement of magnesium present in wine or juice. Along with calcium, magnesium measurements are used to determine water hardness which is an analyte included in our water panels.
Minimum Volume Required: 50mL
IncludesMagnesium
(Units: mg/L, Technique: MP-AES) -
Nutritional Panel
- Various
- |
- 1-2 days
- |
- 250mL
$320.00
Visit product page →Nutritional analysis to provide information for product labeling of alcoholic beverages such as wine, beer, cider and sake.
Note: Please advise Lodi Wine Labs of the serving size required for labeling.
Minimum Volume Requirements: 250mL
Includes
Calories
(Unit: per serving, Technique: Calculation, Method: AOAC OMA 979.07)Carbohydrates
(Unit: grams per serving, Technique: Calculation, Method: AOAC OMA 985.10)Fat
(Unit: per serving, Technique: LWL assumes that there is not fat in these products. If this is in question, the sample can be subcontracted for an additional fee)Protein
Sodium
(Unit: grams per serving, Technique: Various)
(Unit: milligrams per serving, Technique: MP-AES) -
pH Analysis
- Manual
- |
- 24 hours
- |
- 50 mL
$20.00
Visit product page →pH is the measurement of the concentration of hydrogen ions in a solution. The pH of wines are generally between pH 3.00 and pH 4.00. pH is a factor in many aspects of wine and winemaking, affects microbial stability and is used to determine molecular SO2.
Minimum Volume Required: 50mL
Includes
pH
(Units: pH, Technique: Manual) -
Potassium
- MP-AES
- |
- 24 hours
- |
- 50 mL
$35.00
Visit product page →The measurement of potassium in wine and juice. Potassium is an important mineral for yeast growth and is shown to have a relationship with pH and acidity.
Minimum Volume Required: 50mL
IncludesPotassium
(Units: mg/L, Technique: MP-AES) -
Potassium Concentration Product Panel
- Various
- |
- 24 hours
- |
- 100 mL
$80.00
Visit product page →This test estimates the prediction of potassium bitartrate precipitation calculated from the concentrations of potassium, tartaric acid, alcohol and pH.
Results are reported as CPKHT in X10-5
Minimum Volume Required: 120mL
Includes
Potassium
(Units: mg/L, Technique: MP-AES)Alcohol
(Units: % vol, Technique: NIR)
pH
(Units: pH, Technique: Manual)
Tartaric Acid
(Units: g/L, Technique: Sequential Analyzer) -
Tartaric Acid
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$30.00
Visit product page →The measurement of tartaric acid in wine and juice. Acid adjustments are typically made in wine and juice using tartaric acid.
Minimum Volume Required: 50mL
Includes
Tartaric Acid
(Units: g/L, Technique: Sequential Analyzer) -
Titratable Acidity (TA)
- Auto-Titration
- |
- 24 hours
- |
- 50 mL
$20.00
Visit product page →The measurement of titratable acidity reflects the total available hydrogen ions in a wine or juice sample. As tartaric acid is the most prevalent acid found in grapes, TA results are reported as such.
Minimum Volume Required: 50mL
Includes
Titratable Acidity
(Units: g/L, Technique: Auto-Titration) -
Titratable Acidity + pH
- Various
- |
- 24 hours
- |
- 50 mL
$35.00
Visit product page →The measurement of titratable acidity reflects the total available hydrogen ions in a wine or juice sample. As tartaric acid is the most prevalent acid found in grapes, TA results are reported as such.
pH is the measurement of the concentration of hydrogen ions in a solution. The pH of wines are generally between pH 3.00 and pH 4.00. pH is a factor in many aspects of wine and winemaking, affects microbial stability and is used to determine molecular SO2.
Minimum Volume Required: 50mL
Includes
Titratable Acidity
(Units: g/L, Technique: Auto-Titration)pH Analysis
(Units: pH, Technique: Manual) -
Total Dry Extract
- Densitometry
- |
- 24 hours
- |
- 50 mL
$28.00
Visit product page →The measurement of non-volatile matter in wine, calculated using the alcohol and specific gravity of the sample. Total dry extract may be required for export purposes.
Minimum Volume Required: 50mL
IncludesTotal Dry Extract
(Units: g/L, Technique: Densitometry) -
Total Sulfur Dioxide (SO2) - Aeration/Oxidation
- Aeration Oxidation
- |
- 24 hours
- |
- 50 mL
$35.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Aeration/Oxidation) -
Total Sulfur Dioxide (SO2) - Ripper
- Ripper
- |
- 2 days
- |
- 50 mL
$40.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Ripper) -
Total Sulfur Dioxide (SO2) - Sequential Analyzer
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$19.00
Visit product page →Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine.
Minimum Volume Required: 50mL
Includes
Total Sulfur Dioxide (SO2)
(Units: mg/L, Technique: Sequential Analyzer) -
Volatile Acidity VA (as Acetic Acid)
- Sequential Analyzer
- |
- 24 hours
- |
- 50 mL
$31.00
Visit product page →The measurement of acetic acid in a wine or juice, commonly referred to as volatile acidity. It is typically associated with a vinegar aroma and is considered undesirable at elevated levels.
Minimum Volume Required: 50mL
Includes
Volatile Acidity
(Units: g/L, Technique: Sequential Analyzer) -
WineScan Harvest Panel
- Various
- |
- 24 hours
- |
- 50 mL
$50.00
Visit product page →For Grape Juice Only
Description
Affordable rapid wine test using FTIR technology. The results are approximations based on absorbance. Recommended for home winemakers or hobbyists. Not recommended for commercial wines.Includes
°Brix
(Units: % w/w, Technique: FTIR)pH
(Units: g/L, Technique: FTIR)Titratable Acidity (TA)
(Units: g/L, Technique: FTIR)Malic Acid (ML)
(Units: g/L, Technique: FTIR)Alpha Amino Nitrogen (N-OPA)
(Units: mg/L, Technique: FTIR)Ammonia (NH3)
(Units: mg/L, Technique: FTIR)Glucose
(Units: g/L, Technique: FTIR)Fructose
(Units: g/L, Technique: FTIR)Potassium
(Units: mg/L, Technique: FTIR)
- Previous
- Page 1 of 2
- Next