Analysis

Please Note


Test Times Are Target Turnaround Times and Indicated in Business Days 
  • Alpha Amino Nitrogen (N-OPA)

    • Sequential Analyzer
    • |
    • Same Day
    • |
    • 50 mL

    $26.00

    N-OPA refers to one of the two prominent forms (along with NH3) of nitrogen that serve as yeast nutrients. The determination of the enzyme of the reaction or N-OPA is commonly measured along with NH3 to determine YAN (Yeast Assimilable Nitrogen).

    Minimum Volume Required: 50mL

    Includes
    Alpha Amino Nitrogen (N-OPA)
    (Units: g/L, Technique: Sequential Analyzer)

    Visit product page
  • Aluminum

    • MP-AES
    • |
    • 24 hours
    • |
    • 50 mL

    $32.00

    v

    Aluminum

    $32.00

    The measurement of aluminum present in wine or juice.

    Minimum Volume Required: 50mL

    Includes
    Aluminum
    (Units: mg/L, Technique: MP-AES)

    Visit product page
  • Aluminum Packaging Panel

    • Various
    • |
    • 1-2 days
    • |
    • 250mL

    $275.00

    This panel is designed to evaluate suitability of wines for aluminum packaging, and is based on recommendations from major industry suppliers, please consult with your provider to confirm what specifications they require.

    Minimum Volume Requirements: 375mL

    Includes

    chloride (as sodium chloride) 
    Free Sulfur Dioxide (SO2)
    Molecular Sulfur Dioxide (SO2)
    Oxygen - Dissolved O2
    pH
    Total Sulfur Dioxide (SO2)
    Ethanol
    Visit product page
  • Ammonia

    • Sequential Analyzer
    • |
    • Same Day
    • |
    • 50 mL

    $26.00

    v

    Ammonia

    $26.00

    Ammonia refers to one of the two prominent forms (along with N-OPA) of nitrogen that serve as yeast nutrients. The determination of ammonia is commonly measured along with N-OPA to determine YAN (Yeast Assimilable Nitrogen).

    Minimum Volume Required: 50mL

    Includes
    Ammonia
    (Units: mg/L, Technique: Sequential Analyzer)

    Visit product page
  • Brix by Densitometry

    • Densitometry
    • |
    • 24 hours; Juice (Same Day)
    • |
    • 50 mL

    $25.00

    Measurement of the approximate sugar concentration in juice and must reported as percentage by weight.  One gram of sucrose in 100mL of solution is considered a degree Brix. (°Brix)

    Minimum Volume Required: 50mL

    Includes
    °Brix
    (Units: Degrees, Technique: Densitometry)

    Visit product page
  • Brix by Digital Refractometer

    • Digital Refractometer
    • |
    • 24 hours; Juice (Same Day)
    • |
    • 50 mL

    $15.00

    Measurement of the approximate sugar concentration in juice and must reported as percentage by weight.  One gram of sucrose in 100mL of solution is considered a degree Brix. (°Brix)

    Minimum Volume Required: 50mL

    Includes
    °Brix
    (Units: Degrees, Technique: Digital Refractometer)
    Visit product page
  • Density

    • Densitometry
    • |
    • 24 hours
    • |
    • 50 mL

    $27.00

    v

    Density

    $27.00

    Measurement of the mass per volume of wine or juice.

    Minimum Volume Required: 50mL

    Includes
    Density
    (Units: mg/L, Technique: Densitometry)

     

    Visit product page
  • Filterability Index

    • Manual
    • |
    • 24 hours
    • |
    • 750 mL

    $55.00

    The Filterability Index is the measurement of the difference in time from the filtration of 200mL of the wine (multiplied by a factor of two) and the filtration of 400mL of the wine. 

    Minimum Volume Required: 750mL

    Includes
    Filterability Index
    (Units: FI, Technique: Manual)

    Visit product page
  • Free & Total Sulfur Dioxide (SO2) - Sequential Analyzer

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $38.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine. 

    Minimum Volume Required: 50mL

    Includes
    Free and Total Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Sequential Analyzer)

     

    Visit product page
  • Free Sulfur Dioxide (SO2) - Aeration/Oxidation

    • Aeration Oxidation
    • |
    • 24 hours
    • |
    • 50 mL

    $25.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine.

    Minimum Volume Required: 50mL

    Includes
    Free Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Aeration/Oxidation)

    Visit product page
  • Free Sulfur Dioxide (SO2) - Ripper

    • Ripper
    • |
    • 24 -48 hours
    • |
    • 50 mL

    $40.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine.

    Minimum Volume Required: 50mL

    Includes
    Free Sulfur Dioxide (SO2)

    (Units: mg/L, Technique: Ripper)
    Visit product page
  • Free Sulfur Dioxide (SO2) - Sequential Analyzer

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $19.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of free sulfur dioxide is used to determine the amount of SO2 that is not bound to other compounds in juice and wine.

    Minimum Volume Required: 50mL

    Includes
    Free Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Sequential Analyzer)

    Visit product page
  • Glucose + Fructose

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $27.00

    The measurement of glucose and fructose is used to determine the amount of sugar present in juice and wine.  This measurement is also referred to as residual sugar.

    Minimum Volume Required: 50mL

    Includes
    Glucose + Fructose
    (Units: g/L, Technique: Sequential Analyzer)

    Visit product page
  • Glucose + Fructose Panel

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $54.00

    The measurement of glucose and fructose is used to determine the amount of sugar in juice and wine.  This panel gives the individual measurements of both glucose and fructose.

    Minimum Volume Required: 50mL

    Includes
    Glucose + Fructose 
    (Units: g/L, Technique: Sequential Analyzer)

    Fructose
    (Units: g/L, Technique: Sequential Analyzer)

    Glucose
    (Units: g/L, Technique: Sequential Analyzer)

     

    Visit product page
  • Harvest Panel

    • Various
    • |
    • 24 hours; Juice (Same Day)
    • |
    • 120 mL

    $120.00

    v

    Harvest Panel

    $120.00

    A routine set of analysis for juice composition prior to fermentation.

    Minimum Volume Required: 120mL

    Includes
    °Brix
    (Units: % w/w, Technique: Densitometry)

    pH
    (Units: pH, Technique: Manual)

    Titratable Acidity (TA)
    (Units: pH, Technique: Auto-Titration)

    L-Malic Acid
    (Units: g/L, Technique: Sequential Analyzer)

    Glucose + Fructose
    (Units: g/L, Technique: Sequential Analyzer)

    Alpha Amino Nitrogen (N-OPA)
    (Units: g/L, Technique: Sequential Analyzer)

    Ammonia
    (Units: g/L, Technique: Sequential Analyzer)

    Yeast Assimilable Nitrogen (YAN)
    (Units: g/L, Technique: Sequential Analyzer)
    Visit product page
  • Juice Panel

    • Various
    • |
    • 24 hours; Juice (Same Day)
    • |
    • 120 mL

    $40.00

    v

    Juice Panel

    $40.00

    A routine set of analysis for juice and berry composition.

    Note: Sample submissions of grape clusters will be charged a processing fee of $7 per sample for cluster preparation. 

    Minimum Volume Required: 120mL

    Includes
    °Brix
    (Units: % w/w, Technique: Densitometry)

    pH
    (Units: pH, Technique: Manual)

    Titratable Acidity (TA)
    (Units: g/L, Technique: Auto-Titration)


     

    Visit product page
  • L-Malic Acid

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $27.00

    v

    L-Malic Acid

    $27.00

    L-Malic acid is an organic acid found in grapes that is converted to lactic acid during secondary fermentation. The measurement of malic acid is useful for monitoring the progress of malolactic fermentation. 

    Minimum Volume Required: 50mL

    Includes
    L-Malic Acid 
    (Units: g/L, Technique: Sequential Analyzer)

    Visit product page
  • Magnesium

    • MP-AES
    • |
    • 24 hours
    • |
    • 50 mL

    $32.00

    v

    Magnesium

    $32.00

    The measurement of magnesium present in wine or juice. Along with calcium, magnesium measurements are used to determine water hardness which is an analyte included in our water panels.

    Minimum Volume Required: 50mL

    Includes

    Magnesium
    (Units: mg/L, Technique: MP-AES)

    Visit product page
  • Molecular Sulfur Dioxide Panel (SO2)

    • Various
    • |
    • 24 hours
    • |
    • 50 mL

    $40.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of molecular SO2 accounts for the influence of pH on the equilibrium between the forms of sulfur dioxide.   

    Minimum Volume Required: 50mL

    Includes
    Molecular Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Calculation)

    Free Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Sequential Analyzer)

    pH
    (Units: pH, Technique: Manual)

    Visit product page
  • Nutritional Panel

    • Various
    • |
    • 1-2 days
    • |
    • 250mL

    $225.00

    v

    Nutritional Panel

    $225.00

    Nutritional analysis to provide information for product labeling of alcoholic beverages such as wine, beer, cider and sake.

    Note: Please advise Lodi Wine Labs of the serving size required for labeling.

    Minimum Volume Requirements: 250mL

    Includes
    Calories
    (Unit: per serving, Technique: Calculation, Method: AOAC OMA 979.07)

    Carbohydrates
    (Unit: grams per serving, Technique: Calculation, Method: AOAC OMA 985.10)

    Fat
    (Unit: per serving, Technique: LWL assumes that there is not fat in these products. If this is in question, the sample can be subcontracted for an additional fee)

    Protein
    (Unit: grams per serving, Technique: Various)

    Sodium
    (Unit: milligrams per serving, Technique: MP-AES)
    Visit product page
  • pH Analysis

    • Manual
    • |
    • 24 hours
    • |
    • 50 mL

    $19.00

    v

    pH Analysis

    $19.00

    pH is the measurement of the concentration of hydrogen ions in a solution. The pH of wines are generally between pH 3.00 and pH 4.00.  pH is a factor in many aspects of wine and winemaking, affects microbial stability and is used to determine molecular SO2.

    Minimum Volume Required: 50mL

    Includes
    pH
    (Units: pH, Technique: Manual)

    Visit product page
  • Potassium

    • MP-AES
    • |
    • 24 hours
    • |
    • 50 mL

    $32.00

    v

    Potassium

    $32.00

    The measurement of potassium in wine and juice. Potassium is an important mineral for yeast growth and is shown to have a relationship with pH and acidity.

    Minimum Volume Required: 50mL

    Includes

    Potassium
    (Units: mg/L, Technique: MP-AES)

    Visit product page
  • Potassium Concentration Product Panel

    • Various
    • |
    • 24 hours
    • |
    • 100 mL

    $80.00

    This test estimates the prediction of potassium bitartrate precipitation calculated from the concentrations of potassium, tartaric acid, alcohol and pH. 

    Results are reported as CPKHT in X10-5

    Minimum Volume Required: 120mL

    Includes
    Potassium
    (Units: mg/L, Technique: MP-AES)

    Alcohol
    (Units: % vol, Technique: NIR)
     
    pH

    (Units: pH, Technique: Manual)
     
    Tartaric Acid
    (Units: g/L, Technique: Sequential Analyzer)

     

    Visit product page
  • Tartaric Acid

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $30.00

    v

    Tartaric Acid

    $30.00

    The measurement of tartaric acid in wine and juice.  Acid adjustments are typically made in wine and juice using tartaric acid.

    Minimum Volume Required: 50mL

    Includes
    Tartaric Acid
    (Units: g/L, Technique: Sequential Analyzer)
    Visit product page
  • Titratable Acidity (TA)

    • Auto-Titration
    • |
    • 24 hours
    • |
    • 50 mL

    $20.00

    The measurement of titratable acidity reflects the total available hydrogen ions in a wine or juice sample. As tartaric acid is the most prevalent acid found in grapes, TA results are reported as such.

    Minimum Volume Required: 50mL

    Includes
    Titratable Acidity
    (Units: g/L, Technique: Auto-Titration)

    Visit product page
  • Titratable Acidity + pH

    • Various
    • |
    • 24 hours
    • |
    • 50 mL

    $30.00

    The measurement of titratable acidity reflects the total available hydrogen ions in a wine or juice sample. As tartaric acid is the most prevalent acid found in grapes, TA results are reported as such.

    pH is the measurement of the concentration of hydrogen ions in a solution. The pH of wines are generally between pH 3.00 and pH 4.00.  pH is a factor in many aspects of wine and winemaking, affects microbial stability and is used to determine molecular SO2.

    Minimum Volume Required: 50mL

    Includes
    Titratable Acidity
    (Units: g/L, Technique: Auto-Titration)

    pH Analysis
    (Units: pH, Technique: Manual)

    Visit product page
  • Total Dry Extract

    • Densitometry
    • |
    • 24 hours
    • |
    • 50 mL

    $28.00

    The measurement of non-volatile matter in wine, calculated using the alcohol and specific gravity of the sample. Total dry extract may be required for export purposes.

    Minimum Volume Required: 50mL

    Includes

    Total Dry Extract
    (Units: g/L, Technique: Densitometry)

    Visit product page
  • Total Sulfur Dioxide (SO2) - Aeration/Oxidation

    • Aeration Oxidation
    • |
    • 24 hours
    • |
    • 50 mL

    $25.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine. 

    Minimum Volume Required: 50mL

    Includes
    Total Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Aeration/Oxidation)

    Visit product page
  • Total Sulfur Dioxide (SO2) - Ripper

    • Ripper
    • |
    • 2 days
    • |
    • 50 mL

    $40.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine. 

    Minimum Volume Required: 50mL

    Includes
    Total Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Ripper)

    Visit product page
  • Total Sulfur Dioxide (SO2) - Sequential Analyzer

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $19.00

    Sulfur dioxide is used to manage microbial stability and to prevent oxidation. The measurement of total SO2 is the determination of both the free and bound forms of SO2 in juice and wine. 

    Minimum Volume Required: 50mL

    Includes
    Total Sulfur Dioxide (SO2)
    (Units: mg/L, Technique: Sequential Analyzer)

    Visit product page
  • Volatile Acidity VA (as Acetic Acid)

    • Sequential Analyzer
    • |
    • 24 hours
    • |
    • 50 mL

    $29.00

    The measurement of acetic acid in a wine or juice, commonly referred to as volatile acidity. It is typically associated with a vinegar aroma and is considered undesirable at elevated levels.  

    Minimum Volume Required: 50mL

    Includes
    Volatile Acidity
    (Units: g/L, Technique: Sequential Analyzer)

    Visit product page
  • Yeast Assimilable Nitrogen (YAN)

    • Sequential Analyzer
    • |
    • Same Day
    • |
    • 50 mL

    $52.00

    The measurement of yeast assimilable nitrogen is used to calculate the concentration of the total nitrogen in a wine or juice. These components are alpha amino nitrogen (N-OPA) and Ammonia (NH3). This measurement informs nutrient requirement decisions before and during fermentation.

    Minimum Volume Required: 50mL

    Includes
    Yeast Assimilable Nitrogen (YAN)
    (Units: mg/L, Technique: Sequential Analyzer)

    Visit product page